Cat7 Network Ethernet Patch Cable Snagless Shielded (SFTP) , PVC

Cat7 Network Ethernet Patch Cable Snagless Shielded (SFTP) , PVC

EMAIL

Cat7 Snagless Shielded (SFTP) Ethernet Network Patch Cable, 26AWG, 10GBase-T

                    

The Cat7 Snagless Shielded (SFTP) patch cable is equipped with 26AWG , with a high-performance modular plug at both ends. Its snagless design safeguards the RJ45 connectors' locking clips from any harm or breakage during installation. This cable surpasses the Cat7 Ethernet network cable standard, providing a cost-effective solution for indoor Gigabit Ethernet data center applications, and supports up to 10GBase-T and 600MHz within 100 meters of cable.

                                            

Cable TypeCat7 Snagless
Cable Outer JacketPVC CM (Round)
Data Rate10GBase-T
Conductor TypeStranded
Gauge (AWG)26 (7/0.16mm)
StandardISO/IEC 11801
Operating Temperature-20 to +75°C (-4 to 167°F)
Shielding TypeShielded (SFTP)
Length300M
Maximum (Tested) Frequency600MHz
Twisted Pairs4 Pairs
Cable Outer Diameter6.2 ± 0.3
Wire SchemeT568B, Straight
Installation Temperature-10 to +50°C (14 to 122°F)


Product details

High-Bandwidth Transmission

 

Supports a maximum bandwidth of 600MHz at 10Gbps, making it ideal for Fast Ethernet, Gigabit Ethernet, and 10-Gigabit Ethernet.

 


 

Multiple Shielded Ethernet Cabling

 

The cable is easy to plug, and well-protected with an RJ45 modular plug and PVC jacket, which greatly improves the service life of the cable, making it highly compatible with routers, switch boxes, network printers, and other devices.

 


 

Ethernet Network Patch Cable for Data Center Application

                                                                                                               

The durable cable provides stable transmission and slim space-saving features, enabling perfect performance in small enterprises and data centers.

                                                                                                                                                                                                                                                 



 

Professional Fluke Testing Procedures 

                                                                                                                                                   

Each network cable must be strictly tested by Fluke and Wired T568B to ensure superior performance.

 